米兰体育app

TECHNOLOGY jishuzhichi

You Are Here:HOME > TECHNOLOGY > COMMON Q & A

Common troubleshooting methods for machine tools

报警号Alarm NO

信息状态State information

排 除 方 法Methods

1001

机床紧急停止

Emergency stop

排查急停故障后,释放急停开关,报警解除

Remove emergency switch after emergency troubleshooting

1003

计数器计数到达Counter count  complete

工件计数到达设定值,按计数器上的复位键,再按系统RESET键解除报警

Press the RESET button on the counter and then press the system RESET button to cancel the alarm

1007

电机过载保护

Motor overload protection

检查电机过载保护开关,并排查对应电机的过载原因,故障隐患排查完毕后,合上过载保护开关,报警将解除Check the motor overload protection switch and check the overload cause of the corresponding motor. After the troubleshooting is completed the overload protection switch is closed and the alarm will be relieved

1008

卡盘未夹紧

chuck is not clamped

确认夹紧卡盘,报警将解除Confirm clamping chuck, alarm will be relieved

1009

回零报警Back to zero alarm

进行回零操作Go back to zero operation

1019

刀具寿命到达End of tool life

请更换刀具并清除刀具计数,按系统RESET键解除报警Replace the cutter and clear the tool count. Press the system RESET button to cancel the alarm

2016

润滑油位低Low lubricating oil level

添加润滑油Add lubricating oil

2044

进给倍率为零The feed rate is zero

转动进给倍率开关,使倍率大于零,报警解除Rotate the feed rate switch to make the multiplier greater than zero and the alarm is relieved


service hotline:+86-0917-8915000

MONE

Copyright reserved: BAOJI XILI PRECISION MACHINERY CO.,LTD Technical support:DAYOU123 E-mail:bjxlxkc@163.com

ADD:NO.17,ROAD,HIGH-TECH DEVELOPMENT ZONE,BAOJI CITY SHAANXI PROVINCE. TEL:+86-917-8915000(SALES) +86-917-8915002(AFTER-SALES SERVICE) FAX:+86-917-8915009