报警号Alarm NO | 信息状态State information | 排 除 方 法Methods |
1001 | 机床紧急停止 Emergency stop | 排查急停故障后,释放急停开关,报警解除 Remove emergency switch after emergency troubleshooting |
1003 | 计数器计数到达Counter count complete | 工件计数到达设定值,按计数器上的复位键,再按系统RESET键解除报警 Press the RESET button on the counter and then press the system RESET button to cancel the alarm |
1007 | 电机过载保护 Motor overload protection | 检查电机过载保护开关,并排查对应电机的过载原因,故障隐患排查完毕后,合上过载保护开关,报警将解除Check the motor overload protection switch and check the overload cause of the corresponding motor. After the troubleshooting is completed the overload protection switch is closed and the alarm will be relieved |
1008 | 卡盘未夹紧 chuck is not clamped | 确认夹紧卡盘,报警将解除Confirm clamping chuck, alarm will be relieved |
1009 | 回零报警Back to zero alarm | 进行回零操作Go back to zero operation |
1019 | 刀具寿命到达End of tool life | 请更换刀具并清除刀具计数,按系统RESET键解除报警Replace the cutter and clear the tool count. Press the system RESET button to cancel the alarm |
2016 | 润滑油位低Low lubricating oil level | 添加润滑油Add lubricating oil |
2044 | 进给倍率为零The feed rate is zero | 转动进给倍率开关,使倍率大于零,报警解除Rotate the feed rate switch to make the multiplier greater than zero and the alarm is relieved |